Renewable energy developers require precise tracking of land parcels, interconnection queues, and power purchase agreements (PPAs). This interactive template centralizes your pipeline from greenfield origination to commercial operation. Manage utility-scale solar, wind, and storage portfolios with a unified toolset.
✨ Get this free template installed in Salesforce in one day.
Book a free one-hour onboarding session to get started.
Book a free one-hour onboarding session to get started.
Leads
Qualify landowner prospects and corporate off-takers. Accounts
Manage EPCs, utilities, corporate buyers, and municipalities. Contacts
Track land managers, procurement heads, and grid engineers. Opportunities
Negotiate PPAs, site control, and project M&A acquisitions. Campaigns
Execute landowner mailers and community engagement events. Projects
Track utility-scale solar, wind, and BESS development lifecycle. Interconnections
Monitor queue positions, SIS, FAS, and LGIA execution. Land Parcels
Manage APNs, acreage, lease status, and site control milestones.Lead
Robert Vance - Vance Farms
New
Contacted
Site Evaluation
Interconnection Filed
Converted
Details
Notes
Files
Primary Information
NameRobert Vance✎
CompanyVance Farms✎
TitleLandowner✎
Lead StatusSite Evaluation✎
Target TechSolar PV✎
Lead SourceDirect Mail Campaign✎
Lead OwnerAlex Chen✎
Phone555-0199✎
Est. Project Size (MW)100✎
ISO/RTO RegionPJM✎
StateOH✎
Site & Developer Details
Parcel Acreage850✎
Interconnection Proximity1.2 miles✎
TopographyFlat/Cleared✎
Environmental Red FlagsNone Known✎
Site Control StatusEvaluating LOI✎
Substation NameScioto River Sub✎
Target Off-TakerCorporate PPA✎
Est. Yield (MWh/yr)175,000✎
Zoning StatusAgricultural (AG-1)✎
Prevailing Wage ReqYes (IRA Compliance)✎
Site GIS Review
Engineering confirmed the 850 acres are mostly clear of floodplains. The 138kV transmission line runs just north of the property line. High viability for a 100MW array.
LOI Sent
Emailed the initial Letter of Intent for an option-to-lease agreement at $1,200/acre. He is reviewing with his family trust attorney.
Inbound Response
Robert responded to the Q3 Landowner mailer. He wants to diversify farm income after a bad crop yield last year. Very motivated.
Account
Midwest Power Authority
Details
Contacts
Opportunities
Projects
Interconnections
Land Parcels
Notes
Files
Account Profile
Account NameMidwest Power Authority✎
Account TypeUtility / Co-op✎
Industry SectorEnergy & Utilities✎
Websitemidwestpower.example.com✎
Account OwnerJessica Vance✎
Phone555-4422✎
Billing StateIL✎
Market Region (ISO)MISO✎
Portfolio & Financials
Total Operating MW4,500✎
Total Pipeline MW1,250✎
Primary Technology FocusSolar + Storage✎
Credit RatingA-✎
Utility PartnerN/A (Self)✎
Strategic ESG Goal80% Renewable by 2030✎
Build-Transfer Discussion
Met with Sarah Jenkins. They have capital to deploy and are looking to rate-base assets rather than just sign PPAs. We should pivot our strategy on the Springfield Solar project to a Build-Transfer Agreement (BTA).
MISO Queue Delay Impact
The MISO DPP Phase II study for Decatur Storage was delayed 3 months. Sarah requested an updated project schedule showing how we plan to maintain the Q4 2027 COD.
Credit Rating Upgrade
S&P upgraded Midwest Power to A-. This lowers our required credit support for the upcoming PPA negotiations.
Contact
Sarah Jenkins
Details
Notes
Files
Contact Information
Contact NameSarah Jenkins✎
TitleVP of Energy Procurement✎
Contact OwnerJessica Vance✎
Phone (Desk)555-4423✎
Mobile (24/7)555-9005✎
Project RoleEconomic Buyer✎
Engagement & Influence
DepartmentOrigination / Offtake✎
Influence LevelVery High✎
Preferred Contact MethodEmail✎
Technology ExpertisePPA Structuring & Finance✎
Key Decision MakerYes✎
Do Not CallNo✎
IRP Mandate Priority
Sarah emphasized that their latest Integrated Resource Plan (IRP) requires adding 500MW of dispatchable capacity. They strongly prefer BESS and Gas Peaker assets over standalone solar for this cycle.
PPA Pricing Feedback
Received feedback on the Prairie Wind PPA. She stated our proposed $32/MWh is uncompetitive given the recent PTC extensions. We need to sharpen our pencil or pivot to a Build-Transfer.
Opportunity
100MW Solar PPA - Vance Tract
Discovery
Proposal
Negotiation
Closed
Details
Line Items
Notes
Files
Opportunity Details
Opportunity Name100MW Solar PPA - Vance Tract✎
Opportunity TypePPA Origination✎
StageProposal✎
Proposed Capacity (MW)100✎
Target ISO/RTOPJM✎
Opportunity OwnerJessica Vance✎
Close DateNov 15, 2026✎
Probability (%)50%✎
Est. PPA Revenue (Total)$35,000,000✎
Target COD (Com. Ops Date)Dec 31, 2028✎
Generation TechSolar PV✎
Commercial & Development
PPA Rate ($/MWh)$31.50✎
Escalator (%)1.5%✎
Term Length (Yrs)15✎
Delivery NodeAEP-DAYTON Hub✎
Interconnection PhaseSystem Impact Study✎
Environmental StudiesPhase 1 Clear✎
Est. Capital Cost (CAPEX)$85,000,000✎
Projected IRR (%)8.2%✎
Credit RequirementInvestment Grade Buyer✎
EPC StatusRFP Issued✎
ITC/PTC Strategy30% ITC Base✎
Next StepSubmit Final PPA Term Sheet✎
Pricing Update
Midwest Power pushed back on the $32/MWh. We revised the model assuming a 30% ITC rather than PTC, dropping the PPA price to $31.50/MWh. Awaiting their response to the revised term sheet.
Interconnection Risk
PJM delayed the SIS results by another 2 months. We added a force majeure caveat to the COD guarantees in the PPA draft to protect against further ISO queue delays.
Initial Proposal Sent
Submitted the initial 100MW solar proposal into their RFP portal. Offered 15-year terms. Bundled RECs included.
Campaign
Q3 Landowner Mailer - Solar
Details
Campaign Members
Notes
Files
Campaign Information
Campaign NameQ3 Landowner Mailer - Solar✎
StatusIn Progress✎
TypeDirect Mail✎
Focus AreaGreenfield Origination✎
Campaign OwnerMarketing Team✎
Start DateJul 01, 2026✎
End DateSep 30, 2026✎
Region FocusPJM Interconnection✎
Metrics & Tracking
Budgeted Cost$15,000✎
Actual Cost$12,500✎
Target Audience ProfileFarmers > 150 Acres✎
Num Sent2,500✎
Responses42✎
Opportunities Created6✎
Response Rate Tracking
We are seeing a 1.6% response rate which is fantastic for cold direct mail. The "Harvest the Sun" messaging is resonating well with generational farmers in Ohio. Distributing hot leads to the land acquisition team daily.
List Filtration
Filtered the county tax records to exclude any parcels with less than 150 contiguous acres or located more than 3 miles from a 69kV+ transmission line.
Project Asset
Vance Tract Solar 100MW
Origination
Development
Pre-Construction (NTP)
Under Construction
Operating
Details
Notes
Files
Project Identity
Project NameVance Tract Solar 100MW✎
Technology TypeSolar PV✎
Operating StatusDevelopment✎
Capacity (MW AC)100✎
Substation / POI NameScioto River Sub✎
Project OwnerJessica Vance✎
Commercial Ops Date (COD)Dec 31, 2028 (Target)✎
ISO/RTOPJM✎
StateOH✎
Tracking System TypeSingle-Axis Tracker✎
Panel/Turbine OEMFirst Solar (Proposed)✎
Technical & Compliance
Inverter/BESS OEMSMA (Proposed)✎
O&M ProviderTBD✎
Est. Annual Gen (MWh)175,000 (P50)✎
EPC ContractorTBD (Bidding)✎
Environmental ConstraintsNone Known✎
Permitting AuthorityOhio Power Siting Board (OPSB)✎
Tax Equity PartnerPending Selection✎
Decommissioning BondNot Funded (Pre-NTP)✎
NERC TierMedium Impact✎
OPSB Permitting Kickoff
Met with external counsel. Since the array is >50MW, we must file a full certificate application with the Ohio Power Siting Board. Pre-application notice to be sent next month.
BESS Hybrid Addition
Midwest Power asked if we can add a 20MW / 80MWh battery to this project. We need to submit a modification request to PJM to see if it triggers a material modification.
Project Originated
Project record created upon sending the draft LOI to the landowner. Moving to active development pipeline tracking.
Interconnection
PJM-AF2-140
Application Filed
Feasibility Study
System Impact Study
Facilities Study
LGIA Executed
Details
Notes
Files
Interconnection Application
Queue IDPJM-AF2-140✎
StatusActive✎
Utility TerritoryAEP Ohio✎
Voltage (kV)138✎
Study PhaseSystem Impact Study✎
Interconnection OwnerGrid Team✎
Application DateJan 10, 2025✎
Queue Position NumAF2-140✎
Max Injection (MW)100✎
Point of Interconnection (POI)Scioto River Sub 138kV Bus✎
Transmission ProviderPJM✎
Studies & Upgrades
Feasibility Study StatusCompleted✎
System Impact Study StatusIn Progress✎
Facilities Study StatusNot Started✎
LGIA Execution DateTBD✎
Interconnection TypeCapacity Resource (Capacity)✎
Est. Network Upgrade Cost$4,500,000✎
Contingent FacilitiesNone identified yet✎
Security Deposit Paid$200,000 (D3 Deposit)✎
Affected System StudyRequired (Duke Energy)✎
COD Extension ReqNo✎
Material Modification Request
Submitted the Mat Mod request to PJM to add 20MW of BESS to the queue. PJM has 30 days to determine if it requires a restudy. We asserted that it will charge purely from the solar and not exceed the 100MW injection limit.
Affected System Study Notice
PJM notified us that Duke Energy is an affected system due to their nearby 138kV line. Duke will conduct their own study concurrent with the Phase 1 SIS.
Feasibility Results
Feas study came back clean. The Scioto River Sub has a spare bay for our 138kV breaker. Direct assign upgrade costs look very manageable (~$4.5M).
Land Parcel
APN-998822-1
Prospecting
Evaluating LOI
Option Signed
Lease Executed
Owned / Exercised
Details
Notes
Files
Parcel Identity
Parcel NameAPN-998822-1 (Vance Main Tract)✎
APN (Assessor Parcel Num)998822-1✎
Parcel StatusEvaluating LOI✎
CountyScioto✎
Parcel OwnerAlex Chen (Land Team)✎
Total Acreage850✎
Usable Acreage (Build Area)790✎
StateOH✎
Latitude38.7314✎
Longitude-82.9902✎
Control & Zoning
Site Control TypeLease Option (Proposed)✎
Lease Term (Years)35 (Proposed)✎
Lease Rate ($/Acre/Yr)$1,200✎
Option Expiration DateN/A✎
Zoning DesignationAgricultural (AG-1)✎
Mineral Rights StatusSevered (Third Party)✎
Phase I ESA StatusPending NTP✎
Title CommitmentOrdered✎
Easement RequiredYes - Gen-Tie Route✎
ALTA Survey StatusNot Started✎
Mineral Rights Issue
Initial public records search shows the mineral rights were severed in 1982. We will need our title team to track down the current owners and negotiate a surface waiver or drill-site accommodation agreement.
Title Ordered
Ordered preliminary title commitment from First American. Expected back in 14 days.
Usable Acreage Calculation
The GIS team removed the 60 acres containing the floodway and wetlands from the buildable area. That leaves us with 790 usable acres, which is more than enough for a 100MW layout.
