Template Hub Template Hub

Sales Cloud Template for Municipal Utilities & Districts

Municipal Utilities & Districts face unique challenges tracking sprawling infrastructure, capital improvement projects, and diverse customer portfolios. This interactive template organizes service locations, tracks meter deployments, and aligns capital expenditures with municipal growth standards. Manage grid load profiles and capital funding sources all from a unified dashboard.
Get this free template installed in Salesforce in one day.
Book a free one-hour onboarding session to get started.
◄ Back to Leads List
L
Lead

Robert Vance - Vance Property Dev

New
Contacted
Engineering Review
Qualified
Converted
Details
Notes
Files

Primary Contact Information

Related AccountVance Property Dev✎
Lead NameRobert Vance✎
Company / DeveloperVance Property Dev✎
Job FunctionProperty Developer✎
Lead StatusContacted✎
Service InterestNew Subdivision✎
Lead OwnerMike Ross✎
Phone555-0122✎
Load RangeMedium Commercial✎
Connection TypeCommercial Water✎
Primary SourceBuilding Permit Application✎

Technical & Site Requirements

Service Target QuarterQ3 Next Year✎
Extension Required100-500 Feet✎
Metering Requirement2" Compound✎
Council DistrictDistrict 4✎
Load ProfileCommercial Day-Peak✎
Env ClearancePhase I Complete✎
Right-of-Way StatusPrivate Easement Req✎
Plant FeedWater Plant South✎
Pressure ZoneZone 2 (Elevated)✎
Rebate EligibilityEconomic Development Rate✎
Site Tie-in Complexity
Met with developer engineering team. The 100-500 foot extension requires cutting across an active private roadway. We need to secure the private easement ASAP before moving to the proposal stage.
Created by Mike Ross • Aug 01, 2026
Economic Development Request
Developer is asking if this retail park qualifies for the local Economic Development rate tier due to projected jobs. Flagged for review by the rate department.
Created by Mike Ross • Jul 28, 2026
Initial Permit Review
Building permit application pulled from the municipal records. Indicated need for 2" compound meter to support multiple anchor tenants in Phase 1.
Created by System • Jul 15, 2026
◄ Back to Accounts List
Account

Vance Property Dev

Details
Contacts
Opportunities
Service Locations
Meters
Capital Projects
Notes
Files

Organization Details

Account NameVance Property Dev✎
Account TypeCommercial Developer✎
Industry ClassificationReal Estate✎
Billing MethodConsolidated Summary✎
Account OwnerMike Ross✎
Phone555-0120✎
Operating RegionSouth District✎
Customer ClassCommercial✎

Financial & Operational

Payment TermsNet 30✎
Rate ScheduleCOM-2 (Medium General)✎
Delinquency RiskLow Risk✎
Key Account StatusManaged Account✎
Portal RegistrationActive User✎
Restoration PriorityTier 3 (Standard Commercial)✎
Master Meter Request Denied
The developer requested a master meter for the 3 retail pads to save on connection fees. Engineering denied this per municipal ordinance 4.1.2 requiring individual metering for mixed commercial.
Created by Mike Ross • Aug 02, 2026
Transformer Siting Issue
Met with Claire Dunphy regarding the transformer pad siting. They need to move it 15 feet west to avoid the newly drawn drainage swale. Approved by planning.
Created by Linda Hayes • Jul 15, 2026
Consolidated Billing Setup
Dwight from AP confirmed they want all active meters rolled into a single consolidated summary bill for the LLC. Forwarded to customer service to configure.
Created by Mike Ross • Jun 10, 2026
◄ Back to Contacts List
C
Contact

Claire Dunphy

Details
Notes
Files

Contact Information

NameClaire Dunphy✎
Account NameVance Property Dev✎
Project RoleTechnical Evaluator✎
DepartmentEngineering✎
Contact OwnerMike Ross✎
Preferred Contact MethodEmail✎
Portal Access LevelFull Admin✎
Signing AuthorityTechnical Specs Only✎

Communication & Compliance Preferences

Outage Alert PreferenceSMS Text✎
Account StatusActive✎
Primary LanguageEnglish✎
Emergency ContactYes - Primary✎
Newsletter Opt-InCommercial Updates Only✎
Certification LevelProfessional Engineer (PE)✎
Transformer Pad Spec Issue
Claire caught a discrepancy in the clearances for the transformer pad in the original drawings. She submitted the revised CAD files showing the 15-foot shift. Very detail-oriented.
Created by Linda Hayes • Jul 16, 2026
Developer Portal Access
Provisioned Claire with Full Admin access to the Developer Portal so she can upload load calculations and monitor the interconnection queue status for the retail pad directly.
Created by Mike Ross • Jul 05, 2026
Intro Call
Claire is the new Lead PE for Vance Properties. She will be reviewing all municipal utility agreements and line extension drawings going forward.
Created by Mike Ross • Jun 28, 2026
◄ Back to Opportunities List
O
Opportunity

South Park Commercial Tie-in Phase 1

Discovery
Proposal
Negotiation
Contract Signed
In Service
Details
Line Items
Notes
Files

Opportunity Information

Opportunity NameSouth Park Commercial Tie-in Phase 1✎
Account NameVance Property Dev✎
Opportunity TypeInfrastructure Tie-in✎
StageProposal✎
Funding SourceDeveloper Paid (CIAC)✎
Procurement MethodDirect Award✎
Opportunity OwnerMike Ross✎
Project PhaseDesign / Engineering✎
Priority LevelHigh✎
Prevailing Wage RequiredNo✎
Contract VehicleStandard Extension Agreement✎
Service Target QuarterQ3 Next Year✎

Project Parameters & Compliance

Amount (Est. Revenue/Cost)$18,500✎
Close DateNov 15, 2026✎
Probability (%)75%✎
Environmental ImpactCategorically Exempt✎
Regulatory ReviewCity Planning Approved✎
Outage RequiredNo (Hot Tap)✎
Primary Utility BranchWater Distribution✎
Associated Bond MeasureNot Bond Funded✎
Interconnection StatusReady to Connect✎
Material Lead Time IssueStandard Lead Time✎
Supplier Diversity ReqNot Mandated (Private Funds)✎
Contingency Plan ReqStandard Operating Procedure✎
Proposal Delivered to Dev
Emailed the full CIAC invoice and extension agreement to Claire for review. She indicated signature should be swift as it is holding up their grading permit.
Created by Mike Ross • Oct 20, 2026
Hot Tap Approval
Operations confirmed we can do a hot tap on the existing 12-inch main along the frontage road. No service interruption to the adjacent residential neighborhood required.
Created by Mike Ross • Oct 10, 2026
Inventory Check
Warehouse verified we have the 2" compound meter in stock. C900 pipe will be supplied directly by the developer's contractor per the agreement terms.
Created by System • Oct 05, 2026
◄ Back to Campaigns List
C
Campaign

South District Smart Meter Rollout

Details
Campaign Members
Notes
Files

Campaign Overview

Campaign NameSouth District Smart Meter Rollout✎
StatusIn Progress✎
TypeDirect Mail✎
Target AudienceResidential & Small Commercial✎
Campaign OwnerComms Team✎
Launch QuarterQ3 This Year✎
Budget CategoryCapital Bond✎
ChannelUSPS Letter & Door Hanger✎

Outreach Metrics & Details

End DateDec 15, 2026✎
Grant Funding TiedNo✎
Engagement Level TargetInformational Only✎
District FocusSouth District✎
Vendor PartnerMailGraphics Inc.✎
Success MetricLow Call Center Volume✎
Call Center Heads-up
Briefed the customer service floor supervisor. They are expecting a slight bump in calls regarding "opt-out" policies for the smart meters. We provided them with the standard FAQ script.
Created by Comms Team • Sep 28, 2026
Door Hanger Printing
MailGraphics delivered the 15,000 door hangers to the South District field office for the deployment crews to use.
Created by Comms Team • Sep 15, 2026
List Generation
Pulled the billing list for all active Route 5 and Route 6 accounts in the South District. Scrubbed against the Do Not Mail registry.
Created by Comms Team • Sep 01, 2026
◄ Back to Service Locations
S
Service Location

100 Vance Parkway (Retail Pad)

Design/Planning
Engineering Review
Pending Connection
Active Service
Disconnected/Removed
Details
Notes
Files

Location Identity

Location Name100 Vance Parkway (Retail Pad)✎
Service StatusActive Service✎
Feeder LineF-22 South Main✎
Premise TypeMulti-Tenant Building✎
Zoning ClassificationC-1 Commercial✎
Location OwnerMike Ross✎
Primary UseCommercial - Retail✎
Route CategoryRoute 5 (South)✎
Access DifficultyStandard Access✎
Maintenance TierTier 2 (Commercial Standard)✎
Pressure ZoneZone 2 (Elevated)✎

Infrastructure Specifications

Physical Address100 Vance Pkwy, City, ST 12345✎
Service Voltage277/480V (Commercial)✎
Phase TypeThree Phase✎
Transformer Rating250 kVA Padmount✎
Backflow PreventerInstalled & Tested✎
Parcel IDPAR-990-221-44✎
Grid Node AssignmentNode-S102✎
Sewer ConnectionGravity Main✎
Fiber Optic NodeAvailable - Unconnected✎
Right-of-Way AccessPrivate Easement Active✎
Backflow Inspection Pass
Received the annual backflow prevention test from their private plumber. RPZ valve passed. Next inspection due October 2027.
Created by Water Dept • Oct 15, 2026
Transformer Energized
Field crews successfully energized the 250kVA padmount transformer today. Primary voltage is stable. Handed off to metering to set the final AMI unit.
Created by Electric Dept • Oct 01, 2026
Easement Recorded
The 15-foot utility easement for the power drop and transformer pad has been officially recorded with the county clerk. Clear to build.
Created by Legal Team • Aug 10, 2026
◄ Back to Meters
M
Meter

WM-88349201

Inventory
Provisioned
Active - Communicating
Comm Failure
Removed
Details
Notes
Files

Asset Identity

Meter NumberWM-88349201✎
Meter TypeWater - Commercial✎
ManufacturerSensus✎
Model SeriesOmni Compound✎
Operating StatusActive - Communicating✎
Asset OwnerDispatch✎
Reading Frequency15-Minute Interval✎
Communication TechCellular LTE-M✎
Signal StrengthExcellent (> -75 dBm)✎
Asset OwnershipUtility Owned✎
Firmware Versionv4.2.1 (Current)✎

Technical Specifications

Installation DateOct 05, 2026✎
Billing Multiplier1x (Direct Read)✎
Display TypeLCD Digital✎
Calibration StatusFactory Calibrated✎
Enclosure / Vault TypeConcrete Vault✎
MAC Address / ESN00:1A:2B:3C:4D:5E✎
Weather ExposureBelow Grade / Pit✎
Tamper Flag StatusClear (No Tamper)✎
Net Metering EnabledNot Applicable (Water)✎
Replacement PriorityLow (New Install)✎
Initial Provisioning Successful
Meter successfully pinged the cellular network and transmitted its first 15-minute read packet. MDM system confirms data ingestion.
Created by MDM Admin • Oct 06, 2026
Installation Notes
Set the 2" Omni compound meter in the new concrete vault. Confirmed bypass valve is locked and sealed. GPS coordinates updated in GIS.
Created by Field Crew • Oct 05, 2026
Issued from Inventory
Meter scanned out of South District warehouse and assigned to Truck 42 for the Vance Dev work order.
Created by Warehouse • Oct 04, 2026
◄ Back to Capital Projects
C
Capital Project

Vance Parkway Feeder Expansion

Planning/Budgeting
Design/Engineering
Procurement
In Progress (Construction)
Closeout
Details
Notes
Files

Project Overview

Project NameVance Parkway Feeder Expansion✎
Related AccountVance Property Dev✎
Project CategoryElectric Distribution✎
StatusIn Progress✎
Funding ProgramDeveloper CIAC✎
Environmental PhaseCleared (Categorical)✎
Project OwnerMike Ross✎
Est Start DateSep 01, 2026✎
Est Completion DateNov 15, 2026✎
Budget StatusOn Budget✎
Procurement StageAwarded✎
Delivery MethodJob Order Contract✎

Execution & Compliance

Total Budget Amount$185,000✎
Public Disruption LevelMedium (Lane Closures)✎
Traffic Control RequiredApproved Plan Active✎
Regulatory AuthorityCity Public Works✎
Utility ImpactedElectric (Overhead to Underground)✎
Primary ContractorApex Construction✎
Material Supply RiskLow (On Site)✎
Labor RequirementStandard Municipal✎
Grant Compliance StatusNot Applicable✎
Change Order StatusNo Active COs✎
Ward / DistrictDistrict 4✎
Trenching Complete
Apex Construction finished the 400ft trenching along the frontage road. Conduit is laid and encased in concrete. Awaiting backfill and inspection tomorrow.
Created by Field Inspector • Oct 18, 2026
Traffic Control Implemented
Lane closure on southbound Vance Pkwy active as of 9 AM. Message boards are up. City DOT drove by and verified signage placement.
Created by Project Manager • Sep 15, 2026
Notice to Proceed Issued
Final permits cleared and developer CIAC funds verified in escrow. Issued the formal Notice to Proceed to Apex via the Job Order Contract portal.
Created by Mike Ross • Sep 01, 2026