Template Hub Template Hub

Sales Cloud Template for Biomedical Engineering Firms

Biomedical engineering firms face unique challenges tracking device prototyping, clinical trial phases, and strict FDA regulatory submissions. This template provides a centralized system to monitor R&D projects, medical device iterations, and compliance documentation from initial concept to market clearance. Keep your engineering teams, QA leads, and regulatory affairs completely aligned.
✨ Get this free template installed in Salesforce in one day.
Book a free one-hour onboarding session to get started.
◄ Back to Leads List
L
Lead

Mark Vance - Vance Medical Solutions

New
Contacted
Evaluating
Qualified
Converted
Details
Notes
Files

Primary Information

First NameMark✎
Last NameVance✎
CompanyVance Medical Solutions✎
TitleVP of R&D✎
Phone(555) 123-4567✎
Lead OwnerElena Rostova✎
StatusEvaluating✎
Lead SourceTrade Show✎
Budget$100k - $250k✎
Timeline3-6 Months✎
Device ClassClass II (Special Controls)✎

Clinical & Technical Details

Therapy AreaCardiovascular✎
Material TypeMedical Grade Plastics✎
Sterilization MethodEthylene Oxide (EtO)✎
Target MarketUS (FDA)✎
IP StatusPatent Pending✎
QMS RequiredISO 13485 Full✎
ISO CertificationISO 14971 (Risk)✎
Animal Testing NeededIn Vitro Only✎
Clinical Trial PhasePre-Clinical✎
Previous ClearancesNone (First Device)✎
Initial Scoping Call
Mark is looking for engineering support to finalize the housing design of a new portable ECG monitor. They need help ensuring the plastics meet ISO 10993 biocompatibility.
Created by Elena Rostova • Aug 1, 2026
Regulatory Pathway
Client intends to file a traditional 510(k). They have identified a predicate device but need us to perform the gap analysis on the testing data.
Created by Elena Rostova • July 28, 2026
Trade Show Meeting
Met Mark at MedTech Expo. He was impressed by our rapid prototyping capabilities. Sent him a follow-up email with our SLA terms.
Created by Elena Rostova • July 15, 2026
◄ Back to Accounts List
Account

Apex Medical Devices

Details
Contacts
Opportunities
R&D Projects
Prototypes
Regulatory Filings
Notes
Files

Client Information

Account NameApex Medical Devices✎
Parent AccountApex Holdings Group✎
Client TypeMedical Device OEM✎
Phone(555) 321-0987✎
Account OwnerMarcus Cole✎
QMS StatusISO 13485 Certified✎
Master Service AgreementActive✎
SLA TierGold (Dedicated QA)✎

Financial & Audit Details

Billing CityBoston✎
Billing StateMA✎
Vendor IDVND-88192✎
Annual R&D CapEx$1M - $5M✎
Payment TermsNet 45✎
Preferred AuditorTUV SUD✎
Quality Agreement Signed
Apex has officially countersigned the Quality Agreement (QAG) for the upcoming fiscal year. We are authorized to act as their primary engineering firm for Class II devices.
Created by Marcus Cole • Jan 15, 2026
Preferred Supplier Update
We have been added to their preferred supplier list for biocompatibility testing. This should streamline PO approvals.
Created by Elena Rostova • July 5, 2026
eQMS Integration
Apex uses MasterControl for their eQMS. All design history file (DHF) outputs must be formatted for bulk upload into their system.
Created by Marcus Cole • March 22, 2026
◄ Back to Contacts List
C
Contact

Jane Doe

Details
Notes
Files

Contact Information

First NameJane✎
Last NameDoe✎
Account NameApex Medical Devices✎
TitleQA Director✎
Contact OwnerMarcus Cole✎
RoleRegulatory/Approver✎
Influence LevelHigh✎
MedTech Experience10+ Years (Expert)✎

Professional Details

Phone(555) 111-2222✎
Mobile(555) 111-3333✎
Comm PreferenceEmail First✎
Training LevelISO 13485 Lead Auditor✎
Professional DegreeM.S. Biomedical Eng✎
Risk Management Focus
Jane is highly focused on ISO 14971 compliance. Make sure all design proposals explicitly map out the risk matrix and FMEA documents.
Created by Marcus Cole • July 2, 2026
Out of Office Update
Jane will be attending the MedTech Regulatory summit in DC next week. Direct urgent QMS questions to Alice Johnson.
Created by Admin • July 20, 2026
Feedback on Audit
She appreciated our detailed gap analysis report. Said it saved them 3 weeks of internal prep for the BSI audit.
Created by Elena Rostova • Feb 10, 2025
◄ Back to Opportunities List
O
Opportunity

NextGen Defibrillator Design

Discovery
Scoping
Proposal
Negotiation
Closed Won
Details
Line Items
Notes
Files

Opportunity Information

Opportunity NameNextGen Defibrillator Design✎
Account NameApex Medical Devices✎
Primary ContactJane Doe✎
Project CategoryFull Product Development✎
PhaseProposal✎
Delivery ModelTime & Materials (NTE)✎
Opportunity OwnerMarcus Cole✎
StageProposal✎
Amount$450,000.00✎
Close Date9/15/2026✎
Probability (%)60%✎
Start Date10/1/2026✎

Technical & Regulatory Details

Target TherapyCardiovascular✎
Device ClassClass III (PMA)✎
Material ComplexityHigh (Active Implant)✎
Testing RequiredElectromagnetic Compat (EMC)✎
Est. Man-Hours2,500 Hrs✎
SubcontractorsNelson Labs (Tox)✎
Funding StatusSeries A Funded✎
CompetitorBattelle✎
Risk LevelHigh (PMA Pathway)✎
Decision DriverRegulatory Expertise✎
Software PlatformSolidWorks + Altium✎
Warranty TermDesign Transfer Only✎
Pricing Strategy Meeting
Apex is highly sensitive to the timeline. If we can guarantee the FDA submission package by Q3 2027, they will accept the $200/hr blended rate for regulatory affairs.
Created by Marcus Cole • August 2, 2026
Subconsultant Quotes
Received the ISO 10993 testing quote from Nelson Labs. We will pass this cost through directly to Apex with zero markup, per their MSA terms.
Created by Elena Rostova • July 28, 2026
Firmware Complexity
The new defibrillator requires BLE connectivity for data offload. We need to allocate an extra 100 hours to the ELEC-050 line item for cybersecurity hardening.
Created by Marcus Cole • July 15, 2026
◄ Back to Campaigns List
C
Campaign

MedTech Expo 2026

Details
Campaign Members
Notes
Files

Campaign Information

Campaign NameMedTech Expo 2026✎
Target AudienceMedical Device OEMs✎
TypeTrade Show✎
StatusIn Progress✎
Campaign OwnerElena Rostova✎
Event FormatIn-Person Large Expo✎
Clinical FocusGeneral Medical Devices✎
Primary ChannelEvent Booth & Speaking Slot✎

Budget & Metrics

Start Date8/10/2026✎
End Date8/14/2026✎
Lead Gen Goal100+ Qualified Leads✎
Budgeted Cost$45,000.00✎
Actual Cost$48,250.00✎
Expected Revenue$1,500,000.00✎
Booth Setup
The live display of the 3D printed vascular models is drawing huge crowds. Make sure we have enough brochures printed for tomorrow.
Created by Elena Rostova • Aug 11, 2026
Logistics Issue Resolved
The freight company delivered the display cases late, but we got everything set up before the show floor opened.
Created by Admin • Aug 9, 2026
Staffing
Marcus is taking the morning shift to answer technical regulatory questions. Elena is handling initial lead capture.
Created by Elena Rostova • Aug 8, 2026
◄ Back to R&D Projects List
R
R&D Project

PRJ-901: Defibrillator R&D

Concept & Ideation
Feasibility Study
Design V&V
Clinical Evaluation
Design Transfer
Details
Notes
Files

Project Overview

Project NamePRJ-901: Defibrillator R&D✎
DisciplineElectrical/Firmware✎
MethodologyAgile / Sprints✎
Current PhaseFeasibility Study✎
Project OwnerMarcus Cole✎
Health StatusOn Track✎
Start Date2/1/2026✎
Due Date12/1/2026✎
Est. Days300 Days✎
Completion %15%✎

Execution Details

Principal InvestigatorDr. Sarah Jenkins✎
QA LeadAlice Johnson✎
Lab LocationBoston Core Lab✎
Hazard LevelMedium (High Voltage)✎
Ethics Board ApprovalIRB Exempt (Bench Test)✎
Testing Delay0 Days✎
Deliverable TypeDHF Documentation Package✎
Data LoggingPart 11 Compliant eQMS✎
Client Portal StatusActive Data Sharing✎
Invoice StatusMilestone 1 Billed✎
Firmware Sprint 2 Complete
The BLE connectivity module has been integrated into the test board. We are seeing a slight power drain issue in standby mode. Investigating sleep-state registers.
Created by Marcus Cole • August 1, 2026
DHF Template Approved
Apex QA signed off on our Design History File template. All future design inputs must be logged into MasterControl using this format.
Created by Alice Johnson • July 28, 2026
Kickoff Call Summary
Primary goal of the feasibility phase is to miniaturize the capacitor bank. If we can't get it under 200 grams, the overall device weight target fails.
Created by Dr. Sarah Jenkins • Feb 5, 2026
◄ Back to Prototypes List
P
Prototype

PROTO-Alpha-01 (Defibrillator Casing)

In Fabrication
Under Lab Test
Client Review
Design Locked
Scrapped/Failed
Details
Notes
Files

Prototype Specs

Prototype NamePROTO-Alpha-01✎
Related ProjectPRJ-901: Defibrillator R&D✎
Iteration NumberRev 1✎
Build Method3D Printed (SLA)✎
Primary MaterialBiocompatible Resin✎
Assembly LocationIn-House Lab✎
Prototype OwnerElena Rostova✎
StatusUnder Lab Test✎
Due Date8/15/2026✎
Target Cost$1,200.00✎
Actual Cost$1,450.00✎
Build QualityForm & Fit Only✎

Testing & Validation

Sterilization StandardNot Tested (Rev 1)✎
BiocompatibilityMaterial Certs Verified✎
Electrical SafetyPending IEC 60601-1✎
Firmware Versionv0.5.1 Alpha✎
Embedded OSFreeRTOS✎
Drop Test ResultPending✎
Tensile TestNot Applicable✎
Water Ingress (IP)Targeting IP67✎
Client ReviewScheduled for 8/20✎
Next Revision NeedLikely Needed✎
SLA Print Tolerances
The SLA print came out clean, but the battery door hinge is a bit tight. We may need to increase the gap tolerance by 0.2mm for Rev 2 if we switch to injection molding.
Created by Elena Rostova • August 10, 2026
PCB Fit Check
The Rev A PCB fits perfectly into the mounting standoffs. No interference with the top casing shell. Proceeding to drop tests.
Created by Marcus Cole • August 8, 2026
Material Selection
Using Formlabs BioMed White Resin for this print to ensure we can do basic skin-contact handling without issues during the client review.
Created by Elena Rostova • August 1, 2026
◄ Back to Regulatory Filings List
R
Regulatory Filing

510(k) Sub - NextGen Defib

Strategy
Drafting Docs
Submitted
Under Review
Clearance Received
Details
Notes
Files

Filing Overview

Filing Name510(k) Sub - NextGen Defib✎
Related ProjectPRJ-901: Defibrillator R&D✎
Submission Type510(k) Traditional✎
Target RegionUnited States✎
AgencyUS FDA✎
Device ClassClass II✎
Filing OwnerMarcus Cole✎
StatusDrafting Docs✎
Submission DateTarget: 3/1/2027✎
Target Clearance7/1/2027✎
PriorityHigh✎
Expedite Req?No✎

Regulatory & Review Details

Predicate DeviceZoll AED Plus (K123456)✎
Clinical Data IncludedLiterature Review Only✎
QMS DocumentedYes - eQMS Export✎
Notified BodyN/A (FDA Direct)✎
Review CycleDay 0 (Pre-Sub)✎
Filing Fee$14,301.00 (Standard)✎
Fee Paid ByClient Directly✎
Agency ReviewerUnassigned✎
Deficiency LetterNone Received✎
Clearance NumberPending✎
Predicate Device Strategy
Confirmed with Apex that we will use the Zoll AED Plus as the primary predicate. The technological characteristics are identical, though our UI is different.
Created by Marcus Cole • August 1, 2026
Pre-Sub Meeting Request
Drafting a Q-Submission (Pre-Sub) to FDA to clarify if human factors validation testing can be done with simulated use cases rather than live clinical scenarios.
Created by Marcus Cole • July 25, 2026
eCopy Formatting
Ensure all PDF outputs pass the FDA eCopy validation tool before we zip the final folder. We failed this step on the last project and lost 3 days.
Created by Admin • July 15, 2026